For Auction are 2 Like new Solar Taurus 60 Natural Gas 5MW, 50Hz Generation One Turbine Generator Sets. Starting price based on one unit. Total of 2 units available.
Solar Taurus 60 Turbine Power Plant
”Generation One”
Dual fuel piped / Natural Gas fired
Scope of Equipment
Generation One
The following turbine generating equipment is offered for your consideration:
This offer includes for each turbine:
  • Enclosed skid mounted Taurus 60 units (operating on natural gas)
  • Dual fuel option: Units are piped for liquid fuel but the injection nozels are currently set up for natural gas operation. Dual fuel option includes all liquid piping installed with booster pump.
  • SoLoNOx dry now-Nox combustion system. (on natural gas)
  • Each Taurus 60 turbine generator package is capable of producing a nominal 5,200 kW at 13,800 colts in peaking service, subject to site conditions.
  • Complete with all associated turbine inlet and exhaust systems, transformer, fire suppression systems, ladders, gangways and related operational ancillary support items.
  • Each unit comes equipped with a Power Control Room (PCR) Building and the associated ancillary equipment.
  • Units are in excellent condition with very low run time hours each. The units have been in minimal commercial operation. Re certified by Solar and ready for deployment.
  • Units have the wheels removed and the trailer deck lowered to the ground. The turbine unit can be removed from the trailer deck by removing eight bolts from the base of the turbine housing and lifting the unit off of the trailer deck.
  • The trailer (detachable deck) is included in the price each of the Solar Taurus 60 unit. “T-60 is bolted down on each deck.)
  • The double drop deck detachable trailer jeep and stinger come with every second unit.
  • Each PCR building has its own tandem (extendable) drop deck trailer included.
  • Solar factory serviced and maintained.
  • Price quoted is loaded onto your trucks ”EXW Broken Arrow Oklahoma “
I. BASIC PACKAGE
The Taurus 60 Industrial Power Generator (IPG) is a compact, rugged gas turbine generator set that has been designed to meet the requirements for industrial power generation applications.
The unit is provided as a completely integrated module ready for installation. The gas turbine engine, gearbox, generator, control systems, fuel system, lubrication system, start system, and ancillary equipment needed for site operation on natural gas are included with each unit.
Each package includes a sound attenuated enclosure for the turbine generator and a PCR control building to house all generator and turbine control functions. Approximate overall dimensions are: 32 feet, 0 inches (9753mm) long8 feet, 0 inches (2438mm) wide. Approximate height of package is 10 feet, 8 ¼ inches (3258mm) and may vary with ancillary equipment and generator selection. Four (4) lifting gussets are provided on each section. Drip pans are welded  beneath the package frame to collect potential liquid spills. The
drip pans also provided a tight seal for containment of fire suppression agent for packages supplied with an enclosure.
Tube fittings. All tube connections use compression fittings. Tubing and fittings are 316 stainless
steel. Piping. Package piping is designed and fabricated to ANSI B31.3. Electrical System. The Taurus 60 IPG generator set is designated to comply with the
requirements of the National Electrical Code and is intended to be installed in a non-hazardous location per the NEC. Unless otherwise noted, package motors and heaters are rated for 460 VAC, 60 Hertz, 3 phase. Motor space heater are provided for motors over 5 hp (3.75 kW) and are rated for 120 VAC, 60 Hertz, 1 phase. (50Hz Adaptation is OPTIONAL). Fire Detection and Suppression System. The gas turbine enclosure will be provided with ultra violet fire detectors and fire monitoring system. The fire suppression system agent is CO2. In the event of a fire being detected within the package genset, the unit will shutdown, the enclosure
ventilator louvers will close, and horns will sound.
Gas Detection System. Gas detection monitors are provided in the turbine enclosure. Upon detection of 20% LEL, alarms will sound. Upon detection of 75% LEL, the unit will shut down and all louvers will open, and all ventilator fans will activate.

II. GAS TURBINE ENGINE
1. The Taurus 60 gas turbine engine is a single shaft axial flow engine. The output gearbox, including accessory drive pads, is a separate, close-coupled unit
located at the inlet end of the turbine.
2. The engine assembly consist of:
3. Gear unit with accessory drive pads
4. Air inlet collector with flexible flange connection
5. Axilly split case in the vertical plane, eleven-stage axil flow compressor with variable temperatures
6. Geometry control on inlet guide vanes and first two rows of stators
7. Annular Sol
8. SoLoNox combustor with 21 lean premix fuel injectors
9. Three-stage turbine assembly
10. Turbine exhaust collector
11. The components of the Taurus 60 engine are maintained in accurate alignment by mating flanges with plot surfaces and are bolted together to form a ridged
assembly. The speed-reducing gearbox is driven by the compressor rotor shaft. Accessory pads drive the main lube oil pump and other accessories, depending on the application, and support the starter motor.
12. The gas turbine output shaft is mechanically connected to both the compressor and turbine sections of the engine to form a “solid” or “single” shaft  configuration. This feature enhances speed stability and response under constant and varying load conditions – a highly desirable feature in generator applications requiring precise frequently control.

III. SPEED REDUCING GEARBOX
A. The speed-reducing gearbox is an industrial design manufactured by Solar specifically for the Taurus 60 IPG generator set. The gearbox mounts directly on the Taurus 60 gas turbine to reduce engine speed to 1800 rpm (60Hz).

IV. GENERATOR
Generator Rating. Generator nameplate rating per NEMA standards is 6,625 Kva at 0.8 power factor (5,300kw) 13,800 volts at 104ºF (40ºC), 3281 ft (1000m) elevation for continuous duty. The generator is rated so that the generator will not limit turbine performance over the range of site ambient temperatures.
  • Generator Standard Features
  • Sleeve Bearings with pressure fed sumps
  • Six-lead WYE connection
  • Terminal box
  • Form wound stator windings
  • Damper windings
  • Rotor balance to 125% rated speed
  • Permanent magnet pilot exciter
  • Anti-condensation space heaters
  • 300% short circuit capability for 10 seconds
Overload capacity per NEMA:
  • 150% rated current for 1 minute (b) 110% for 2 hours
  • Voltage Regulator Characteristics
  • Solid state
  • Single-phase sensing
  • ±10% voltage adjustment range
  • 0.5% steady state voltage regulation
  • Reactive load sharing to within 5% nameplate rating
  • Crosscurrent compensation capability
  • Wave From Characteristics
Deviation Factor
Harmonic Content (maximum)
Telephone Interference Factor
Balanced Residual
Voltage Drift. The change in voltage will not exceed 1.0% over a 30 minute period when the generator is operating at rated voltage and 0.8 to 1.0 power factor and with a constant load between no load and full rated load.
Generator Voltage. The generator output is 13,800 Volt, 3 phase, 60 hz.  Insulation conforms to NEMA class F with class F (105ºC) temperature rise.

V. TURBINE STATE SYSTEM
A direct drive AC motor is provided to state the Taurus 60 engine. A variable frequency drive [VFD] motor controller is included for installation in the motor control center [MCC]. 3 phase AC power is required at 460VAC, 60Hz, 250 Amperes. The control system provides all required sequencing to quickly and reliably state the turbine.

VI. FUEL SYSTEM
The fuel system, in conjunction with the electrical control system, includes all necessary components to control the fuel pressure, to schedule fuel flow during start-up, and to modulate fuel flow during operation.
Natural Gas Fuel. A natural gas fuel system is provided with all components necessary to maintain turbine speed to provide a constant generator output frequency and/or load depending on the generator set mode of operation. Solar’s Specification ES 98 contains the specific fuel requirements.

The natural gas fuel system includes primary fuel shutoff valve, Pilot-operated secondary fuel shutoff valve.
  • Electric fuel actuator
  • 10-micron pilot gas filter
  • 2 fuel injector assemblies
  • Valve check pressure switch
  • High gas fuel pressure shutdown switch
Gas strainer Systems requirements for the natural gas fuel are as follows:
Requires a constant supply of gas at a maximum flow demand rate of 32.2 mn3/min (1200 scfm) at 1725-kpa-gauge (225 psig) minimum pressure. Gas fuel pressure is used to operate the fuel system pilot valve.
The gas fuel should be free of sulfur, contaminants, entrained water, and liquid hydrocarbons Gas fuel must conform for Solar’s Specifications ES 9-98.

VII. LUBE OIL SYSTEM
A complete lube oil system suitable for operation with lube oil conforming to Solar’s Specification ES9-224 is included. The lube oil system provides oil to the bearings in the Taurus 60 gas turbine engine, gearbox and generator. Instrumentation, flow control and on frame piping are included.
Main Lube Oil Pump. An engine driven lube oil pump is provided with suction strainer. Post Lube Backup Pump. A 1.5hp (1.1kW) AC motor driven pump is provided to supply post operation lube oil flow in the event of power failure. Power is provided by a 24 VDC battery system through a VFD/inverter.
Drain Line Sight Glasses. Sight glasses are provided on the drain lines from all gas turbine, generator and gearbox bearings. Note that some of the gas turbine bearings have a common drain line.
Lube Oil Tank. A 420-gallon operating capacity carbon steel lube oil tank is provided. The lube oil tank is integral with the package frame. Lube oil level indicator, fill connection with inlet strainer and drain connections are included.
Lube Oil Tank Heater. A thermostatically controlled 4.5kW lube oil tank heater is provided. Electric power requirements are 460 V, 60 Hz, 3 Phase.
Lube Oil Vent Separator. An off skid mechanical coalescer element is provided to remove oil vapor from the lube oil tank vent. Recovered oil drains back to the lube oil tank. Interconnect piping between the frame flanges and the vent separator is not included in Solar’s scope. The vent separator is nominally rated for less than 0.2 gallons/day (0.76 L/day) oil loss.
Lube Oil Cooler. An air/oil lube oil cooler is provided. The fan is driven by a 3.7 kW AC motor. The lube oil cooler is designed for off skid installation. Interconnect piping between the frame flanges and the lube oil cooler is included according to current design.
Lube Oil Type. Lube oil is not included. The lube oil supplied must be consistent with the requirements of Solar specifications ES 9-224.
Lube Oil Filter. Single 5-micron oil filter units are provided with drain, fill and vent valves.

VIII. CONTROL SYSTEM
Solar Control System. The Turbotronic control system is provided and is a highly integrated programmable logic controller (PCL) based control system. The control system is installed on the package frame to minimize interconnect wiring. The control system includes a microprocessor, remote communications modules; chassis based and flex input/output modules, line synchronization module, power supplies and a hardware
backup shutdown system. The control system provides for control of all phases of package operation to include state and shutdown sequencing, normal operation, and malfunction shutdown.
Vibration Monitoring. Vibration monitoring is provided to include three proximity probes, one per bearing, on the Taurus 60 engine. One accelerometer is provided with the gearbox. Two velocity transducers, one per bearing is provided with the generator. Preset warning indications and malfunction shutdown initiations are provided.
Temperature Monitoring. Temperature monitoring is provided to include the Taurus 60 engine thrust bearing, lube oil drains, and lube oil header and the generator bearings and stator windings. Preset warning indications and malfunction shutdown initiation are provided. Ambient, lube oil tank and enclosure temperatures are also monitored.
Audible Alarm. An audible alarm horn is provided to sound whenever the unit has an alarm or shutdown condition. A horn silence push button is mounted on the face of the control panel.
Local Display. The control system is installed on the package frame in weatherproof enclosures. A digital control panel (DCP) with all of the necessary switches and indicators is provided. In addition to display of “first out” malfunctions, the DCP can display:
  • System summary/normal running data System status
  • Digital display of engine and generator parameters
  • Alarms and Shutdowns
  • Engineering Units. Temperature data is displayed in ºF. Pressure data is displayed on pounds per square inch (psi).
Language. Package labels and screen displays are in English.
Supervisory Interface. An RD 232C/422-interface module is provided to give the user’s supervisory computer access to the Turbotronic control system data. Limited control capability is provided to allow the supervisory computer to start and stop the unit, reset alarms, and raise/lower speed and load set points. The communications protocol is Allen Bradley’s DF1. The
interface module may be located up to 10,000 feet (3,048 meters) from the turbine control system and located up to 50 feet (15 meters) from the supervisory computer for the RS 232C module or 4,000 feet (1,219 meters) for the RS 422 module. The modules are “table top” units and require 120 Vac, 50/60 Hz power.

IX. GENERATOR CONTROL AND MONITORING
Integrated monitoring and control of the generator is provided using a specially designed module in the PLC to receive input data from potential and current transformers. The system calculates real and reactive power, power factor and the variables required for synchronization.
Automatic Synchronizing. An automatic synchronizer is provided with the control system to automatically synchronize the unit to the bus through push-button control on the digital control panel (DCP) or by receipt of an appropriate remote signal. A synch check relay is provided as an additional permissive and for backup protection.
Motorized Voltage Adjust. Raise/lower voltage push button control is provided on the digital control panel to control a motorized potentiometer for voltage control. An additional raise/lower switch, supplied by others, may be used to control voltage from a remote location.
KW Controller. A kW import controller is provided to control the real load (kW) on the generator set while operating in parallel with a utility or other large source. The kW controller monitors the load imported from the utility source and adjust the generator set fuel flow to maintain a pre-set level of imported power on the utility at all times. This control mode is for applications where it is desired to prevent any power from being exported to the utility. Protection against excessive kW load while in parallel with a large source is provided by the control system “T5” temperature limiter. The kilowatt load level select switch and adjustment is located on the digital control panel.
KVAR/Power Factor Controller. A kvar/power factor controller is provided to maintain a constant reactive load (WAR) output or constant power factor (pf) on the generator set while the unit is operating in parallel with a utility or other large source. The controller applies a signal directly to the voltage regulator adjust circuit to maintain a constant reactive load or power factor with
changes in the infinite bus voltage level. The system incorporates a set point adjust rheostat to set the desired WAR or pf, a selector switch to choose WAR or pf control mode, and a switch to turn the controller on and off.

X. ADDITIONAL ANCILLARY EQUIPMENT
The following additional ancillary equipment is also provided for the turbine-generating package:
a. Neutral Ground Resistor
b. Auxiliary Load Transformer (13.8 kv:480 V, 60 Hz). This transformer eliminates the requirement for an alternate 480VAC shore power supply.
c. Liquid Fuel Boost Pump (with dual fuel option)
d. XI. DRAWINGS
e. One set of standard drawings is provided with each turbo machinery package.
f. XII. OPERATION AND MAINTENANCE MANUALS
g. One set of operation and maintenance manuals are provided with each turbo machinery package.
SECTION 3
POWER CONTROL ROOM (PCR) BUILDING FOR A SOLAR TAURUS 60 POWER
GENERATOR SET:
Utility Grade 15KV class metal clad paralleling switchgear:
  • The Power Control Room Building contains the following equipment:
  • PCR HVAS system
  • Generator Main Circuit Breaker 15KV
  • Auxiliary Transformer Feeder Circuit Breaker
  • Bus pts, Feeder cts, Metering cts and pts, and Protective Relay Module
  • Lightning Arrestor and Surge Capacitor
  • Motor Control Center (Serves Turbine Generator 480VAC Auxiliary Loads)
  • 120VDC Turbine Generator Battery System with Charger
  • Dedicated 120VDC Switchgear Battery System with Charger


 

 Request further information


Disclaimer:  Descriptions and photos are posted by the owners of the equipment.
Bid-on-equipment.com cannot guarantee their accuracy.
No warranty is made regarding condition or suitability for any purpose.
Contact us to arrange an inspection or a conference call with the owner.
Inspection is encouraged.  Items purchased cannot be returned.
Click on photo to enlarge

SOLAR Taurus 60 5MW 50Hz Natural Gas Turbine Gen Photo #1

ask seller a question
Request
More
Information



bid
Bid on
this item

 
Bidding

USED merchandise
Offered AS-IS and
with all faults.  The buyer is responsible for all shipping cost. There may also be skidding or crating charges.

Please read the
terms of sale
before bidding


Payment may be by
wire transfer,
certified check
bank check, or
company check with
letter of guarantee



Contact our sales department:
1-847-683-7720

You are bidding on:   SOLAR Taurus 60 5MW 50Hz Natural Gas Turbine Gen
(The quantity you are bidding on is one)


Buy it Now For:  $2,800,000.00 Ask the seller a question
Current High Bid:  $1,690,000.00 Help Bidding
Enter Your Bid:  $ .00   (US dollars) Terms of Sale
The next bid must be at least: $1,690,500.00
This is not an absolute auction.   The seller may or may not accept a bid below his asking price.
If your bid is near what the seller is willing to accept, he will likely make a counter offer.
A seller can end the bidding at any time if he accepts a bid, so bid your highest and best.

If you have any questions, please ask them BEFORE you bid.
You can click here to ask a question.
Do not bid unless you intend to buy.  Your bid is a legal contract.


This listing expires 1/24/2010 12:02:40 PM


Generators > SOLAR Taurus 60 5MW 50Hz Natural Gas Turbine Gen
This item has been viewed times.

Newest Listings Home Latest Bids

Copyright © 2001-2007 Bid on Equipment. All Rights Reserved.
No part of this web page may be reproduced in any way,
or by any means, without the prior written permission of Bid on Equipment.
Powered by auction software from rainworx.com v-1.1.829bideqG4