ATI-RTO converts hydrocabons as found in many industrial process streams into carbon dioxide and water through the process of high temperature oxidation. The beds of heat exchange media provide up to 95% heat recovery to keep operating costs to a minimum. Two reinforces insulated chambers filled with high temperature heat exchange media. The specifications listed below are how the equipment was used and was taken off line early March 2021, in good working condition.
* Design Process Air Flow - 4500 SCFM
* Minimum Process Air Flow - 1125 SCFM
* Design Process Temperature, 200 degrees F
* Design Solvent concentrate, 168 #/hr
* Electrical Power requirement for main control panel (CP-101)(460 VAC/3 phase/60Hz) Amps - 33.84 F.L.A.
* Electrical Power requirement for main process fan (460 VAC./3 phase/60Hz), Amps - 34.0 F.L.A.
* Heat Recovery Efficiency, 95 %
* Hydrocarbon Destruction Efficiency 98%
* Compressed Air Requirements @ 90 psig, 720 SCFH
* Natural gas requirement @ 5 psig, 1150 SCFH
Additional Prep Fees May Apply