Browse our other Freeze Tunnels
Machine Specifications: 1. Belt: 24" wide with 4'-6' active length; 2. Dwell time 2-20 minutes; 3. Habisat 2532 Acetyl material; 4. driven by 1/20th HP 90 V Dayton DC gear motor with 200 to 1 reduction; further reduction of 9.33 to 1 taken with chain drive; motor controlled by Dart Variable speed drive; 5. belt has 6" high product guards to keep product on belt; 6. Fan Coil unit: coil is Krack copper aluminum coil with 4 FPI; circuited for DX Freon feed; has electric defrost controlled by time clock, shaker stops automatically during defrost to stop feed; Fan is a Dayton 1 hp belt drive tube axial fan and provides air velocity of 390 FPM measured at the belt; air volume can be changed by changing pulley on drive motor; 7. Refrigeration system: compressor Hussman model KP014-5L5 air cooled condensing unit with 6 HP Copeland semihermetic compressor mounted in one end of the freezer; system uses R507 freon; 8. unit provides 5 F air at the belt when running 100 lb per hour of product 9. Control panel: with 20 amp 460 V min breaker; unit has Partlow 7000 chart recorder to record air temperature; has control switches for the liquid line solenoid, fan10. Total length: 18' feet, width 8' feet, height 6' foot; weight: approximately 7,000 pounds.Additional Prep Fees May Apply