Qiagen TissueLyser II Sample Disruption Preparation Unit Homogenizer Disruptor
**This item was tested to specifications. Unit has slight wear from normal use. Buyer can expect a working unit with 30-day warranty. (Does not include Adapter set). See photos for details.
(Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)
For medium- to high-throughput sample disruption for molecular analysis
The TissueLyser II simultaneously disrupts multiple biological samples through high-speed shaking in plastic tubes with stainless steel, tungsten carbide, or glass beads. Using the appropriate adapter set, up to 48 or 192 samples can be processed at the same time.
The TissueLyser II is well-suited for high-throughput disruption of human, animal, and plant tissues, bacteria, and yeast. Highly reproducible purification of high-quality DNA, RNA, miRNA, and protein is achieved, even with difficult-to-lyse tissues.
The ability to process up to 192 samples per run makes the TissueLyser II the ideal front-end solution to access biological information for genomics, transcriptomics, and proteomics applications. For next-generation, high-throughput sequencing technologies, the TissueLyser II is the disruption instrument of choice.
A wide range of QIAGEN sample purification kits are compatible with the TissueLyser II, and sample purification can be performed manually or can be automated using the QIA cube, QIA symphony SP, EZ1 Advanced, or BioRobot or BioSprint workstations.
Convenient and secure disruption process
Adapter sets optimized for high-throughput disruption
Wide range of accessories available
Reproducible results with difficult-to-lyse tissues
Front-end solution for QIAGEN automation
Manufacturer's Specifications:
Disruption principle
High-speed shaking of samples in 1.2 ml collection tubes or 2 ml microcentrifuge tubes with stainless steel or glass beads
Typical run time
15 sec - 2 x 3 minutes at 1530 Hz
Technical data
100 120/220 240 V, 50/60Hz; variable speeds from 3 to 30 Hz (1801800 oscillations/minute)
Kits compatible with instrument
All kits for purifying RNA/DNA/Protein
Protocol/main application on this intrument
Sample preparation/sample disruption
Throughput
2 x 96 collection microtubes (1.2 ml) or 2 x 24 microcentrifuge tubes (2ml)
Features
Convenient and secure disruption process. Adapter sets optimized for high-throughput disruption. Wide range of accessories available (e.g., grinding jar set to process large samples). Reproducible results with difficult-to-lyse tissues. Front-end solution for QIAGEN automation.
Technology
Bead Mill
Additional Prep Fees May Apply