Available Immediately :
Brand New CaptiveAire Rooftop HVAC Unit. (CASRTU1-I.150-18-6T-DOAS RTU) with Curb. Never installed (ordered accidentally). Details below. Willing to provide original purchase documentation and receipts to a serious prospective buyer. *** Ships on (2) skids *** Please contact via BOE for weights and DIMS.
CASRTU1-I.150-18-6T-DOAS RTU with Indirect Fired Heat and 18" Direct Drive Mixed Flow Plenum Fan, 1 Furnace, Electronic Full Modulation, Constant 80% Efficiency, and 6:1 Max Turndown for NG, (5:1 Max Turndown for LP). Stainless Steel Burner and Heat Exchanger. Variable Speed Cooling. Supply Fan handles 2400 CFM @ 1.000" wc ESP, Fan runs at 1762 RPM. Heater supplies 114000 BTUs. 47°F Temperature Rise. [Fuel: Natural Gas] Input: 140741 BTUs. Supply Motor: 2.000 HP, 3 Phase, 460 V, 60Hz, 2.7 FLA, ODP, Premium (E-Plus3) Eff. Down Discharge - Air Flow Left -> Right
- MUA-50-90°F Space Temp Control • Space Sensor Ships Loose • Heating/Cooling Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA.
- Gas Manifold for RTU 1-1 GM - BTU 0 - 400001 - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-66
- Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
- Gas Pressure Gauge, 0 to +10 Inches Wc., 2.5" Diameter, 1/8" Thread Size, Rear Thread
- CFM monitoring for MUA units. Uses rivet nuts, 1/4" airflow tubing and push to connect fittings.
- Ship Loose Gas Strainer. To be installed upstream of unit connection. 3/4" Connection
- Single Point Electrical Connection for RTU. QNTY 1 750va Transformer Used. If a Non-DCV Prewire controls this unit, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
- Low ambient cooling controls down to 0F ambient temperatures. To be used in recirculating applications.
- 2" Merv 8 Filters for Size 1 RTU.
QTY 4, 16 x 16 x 2 Merv 8 Filters
- Overheat Stat factory set at 80°F and 10 minutes. Prevents unit from overheating the space when cooling.
- VFD factory mounted and wired in unit control vestibule.
- Specially sized orifices for applications above 2,000', notify engineering.
- RTU Size 1 Down Discharge
- Remote Room Sensor Option. Wall Mountable 10k Temp and Humidity Room Sensor Included.
- Size 1 RTU Curb Duct Hanger - Adjustable Duct Hanger Support Brackets installed for both return and discharge duct.
- RTU Size 1 Down Return
- RTU Size 1 Hail Guard for outdoor coil. Includes magnets and washers for installation.
- RTU Manual 0-10V Intake Control. Actuator Control by 0-10VDC Output on Control Board. Intake Position Controlled Manually via HMI.
- VAV (Variable-Air-Volume) Wiring Package for Commercial Fans.
Manual Speed Control Variable Frequency Drive Included
- ESV152N04TXB571 - Variable Frequency Drive - 2 HP Max., 400/480 V, Three Phase, 4.0/3.5 A Max., NEMA 1 Enclosure, with 2RJ-45 FOR MODBUS
- KDRULA1L - 480V 4.2A Line/Load reactor. Used with VFD.
Use VFD spreadsheet to determine which VFD HP can be associated with reactor.
Replacing:
PN: RM0004N65
- Mount Load Reactor in Fan.
- Fixed enthalpy controls that modulate OA percentage based off temperature and relative humidity set points.
- Barometric Relief for RTU Size 1 Economizer
- GFCI 15 amp Convenience Outlet For RTU1 Enclosure. 120V power supply by others. Includes receptacle, jbox & cover.
- 6 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
- RTU Compressor Oil Sensor Factory Installed.
- 6 Ton Heat Pump Modulating Reheat Option for Space Control
- Commercial Smoke Detector Interlock (Detector By Others)
- VERIZON CELLULAR KIT, WIRED ANTENNA AND VERIZON DATA FOR 1 YEARS. USED WITH FAN.
- Bearing Protection Shaft Grounding Ring - Min Dia = 0.981 Max Dia = 1.020 - Used On Motors With 1" Diameter Shaft. Epoxy Mounting.
- RTU-14 Curb CRB41X71X14INS Insulated On Fan #1 Flat Curb CASLink Monitoring
- Full Bottom Curb Corner. Base flange corners fully welded or staked by factory.
Additional Prep Fees May Apply