SAFETY STORAGE FOR FLAMMABLE & HAZARDOUS MATERIAL (Max 60 Gal Cont.) EXCELLENT CONDITION, VENTILATOR, INTERIOR LIGHTING
The unit is intended for the storage of Class I, II & flammable liquids & hazardous materials contained in 60 gal max. containers.
BUILDING CONSTRUCTION & OCCUPANCY EVALUATION: Use Group H, Division 2 Occupancy - High Hazard, Type V Frame Construction, Unprotected, Type 3A Frame, Protected, 1500 Sq. ft Max. Occupancy, Design Roof Live Load - 40 PSF., Design Wind Load-38PSF (100 MPH), Design Floor Live Load-250 PSF, Seismic Design-Zone 4 UBC
TEMPERATURE CLASSIFICATION: For handling materials with ignition temperatures not less than 392 deg F (200 deg C) - T3
TYPE OF ENCLOSED WIRING SYSTEM: Insulated conductors in steel Intermediate Metal Conduit
ELECTRICAL RATING POWER SUPPLY: 60A, 120/240 V, 1-Phase, 3-Wire
QUANTITY OF CIRCUITS PROVIDED: 1
FIRE RATED: Ceiling/Roof - 1 Hr. Ventilation/Damper-1-1/2 Hr Exterior Wall Structure-2 Hr Roof Covering-Class A Door/Frame-1 1/2 Hr
Permanently Installed Factory Appliances: Interior Lights-Hubbell EMI/EBF Series Factory Sealed. Ventilator-Penn Ventilator Model Breezex, Bell-Wheelock 43T-G6-115 Includes all field installed plumbing or mechanical systems, including sprinkler systems, overflow drainage systems and the installations of portable fire extinguishers which are subject to local inspection.