Browse our other Lab Equipment
Molecular Dynamics Typhoon 9410 Variable Mode Imager w/Typhoon Blue Laser ModuleIncludes Typhoon Scanner Control 4.0 and ImageQuant 5.2. software and Typhoon Blue Laser Module (Serial No.: 94874)**SELLING AS-IS**Used, removed from working environment but unable to get communication between system and software. Some minor cosmetic wear from regular use, please see photos for details. Includes everything pictured. DESCRIPTION:Typhoon instrument Scans exposed Storage phosphor screens, fluorescent samples, and chemiluminescent samples.Molecular Dynamics (GE) Typhoon 9410 Variable Mode Imager unites proven storage phosphor auto-radiography technology with four-color non-radioactive fluorescent labeling techniques. For DNA RNA and protein samples with the Molecular Dynamics Typhoon 9410 you may choose from:storage phosphor auto-radiographydirect blue-excited fluorescence (457 488 nm)direct green-excited fluorescence (532 nm)direct red-excited fluorescence (633 nm)chemiluminescenceSPECIFICATIONS: Scan area 35 43 cmSensitivity (limit of detection)Storage Phosphor 14C (1 h exposure 200 and 100 m only): 488 nm excited fluorescence 100 amol FAM end-labeled DNA primer in 12% polyacrylamide gel sandwich 0.4 mm thick532 nm excited fluorescence 200 amol HEX TMR ROX and 400 amol FAM end-labeled DNA primer in 12% polyacrylamide gel sandwich 0.4 mm thick633 nm excited fluorescence 200 amol Cy5 end-labeled DNA primer in 0.4 mm thick 12% polyacrylamide gel with TBE bufferPixel size 1000 500 200 100 50 25 and 10 m selectableSpatial resolutionAuto-radiography 2 line pairs/mm for lines drawn with 14C ink.Blue-excited fluorescence 10 line pairs/mmGreen-excited fluorescence 10 line pairs/mmRed-excited fluorescence 10 line pairs/mmUniformity 5% over entire scan areaPixel accuracy 0.15%Data format 16-bit (65 536 levels) TIFFLinear dynamic range and linearity Five orders of magnitude (100 000:1) with less than 7.5% relative standard deviation for entire dynamic range.Red light source Type: 10 mW Helium-Neon laserEstimated average lifetime: 10 000 h Wavelength: 632.8 nmGreen light source Type: 20 mW solid-state doubled frequency SYAG laserEstimated average lifetime: ~ 10 000 h Wavelength: 532 nmBlue light source Type: 30 mW all blue lines Argon ion laserEstimated average lifetime: ~ 5000 h Wavelength: 488 nm (20 mW) and 457 nm (4 mW)External interface 10 Base-T Ethernet using TCP/IP protocolSoftware Scan control software for Windows operating systemPower requirements 115/230 V (switchable) 50-60 Hz Dimensions (W D H) Instrument: 118 78 48 cmBlue laser module: 30 78 48 cmSafety certifications UL 3101 CAN/CSA C22.2 No 1010.1 EN 61010-1 EN60825-1 EN 61326 CE Marking (LVD 73/23/EEC EMC 89/336/EEC) CDRH (FDA) Subpart 21 CFR Ch.1-Part 1040. (Please contact your local GE Healthcare office for the latest list of certifications.)FEATURES: Versatile system handles gel sandwiches agarose and polyacrylamide gels membranes microplates and even microarrays.Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.Red- green- and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis increasing throughput and saving time.Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H 14C 125I 32P 33P 35S and other sources of ionizing radiation.Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.Click Link to View Manufacturer's InformationBlue laser module: Contains the blue laser and the power supply for the laserAdditional Prep Fees May Apply