NuAire LabGard ES Class II, Type A2 Biological Safety Cabinet NU-540-400
***LabGard BSC is preowned with minimal wear from normal use. UV, lights, blower all working. Unit does not include base stand. 30-day warranty included with purchase. See photos for details.
(Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)
The NU-540 integrates a powerful DC ECM motor with flexible plenum into a robust steel structure to provide long-term, cost effective containment configured for basic research and clinical applications.
The NU-540 features a DC ECM motor to economize energy while distributing laminar airflow through a flexible plenum and offering enough power to overcome HEPA filter loading and minimize filter changes. This design provides the user with a work zone whose side and back walls are constructed from a single piece of stainless steel for enhanced containment and easy cleanability. Fluorescent lighting illuminates the procedure inside the cabinet while a dished work tray traps liquid spills and a cord-pass through in the side wall facilitates the use of small electrical devices in the work area. Users easily monitor cabinet performance through the Aeromax control system that displays the pressure in the cabinets internal airflow plenum. The NU-540 is configured to meet the needs of most clinical and research applications, offering containment that meets the NSF/ANSI 49 standard that is followed in most of the Americas.
AeroMax Control System
The AeroMax control system visualizes airflow plenum pressure through a series of multicolored lights and activates both an audible and visual alarm whenever cabinet performance departs from normal parameters.
Ultra High Efficiency Motor
A single DC ECM motor with a precision-engineered forward curved fan powers airflow through the biosafety cabinet. The ultra-high efficiency motor lowers energy costs and reduces noise pollution but is powerful enough to extend filter life. The one motor design allows for easy certification and airflow balancing. In addition, it provides enough power to compensate for HEPA filter loading, reducing filter changes and lowering the total ownership cost.
HEPEX Zero Leak Airflow System
Our signature flexible plenum design complements the ultra-high efficiency motor to uniformly distribute the downflow air across the supply HEPA filter into the work zone in a laminar or unidirectional pattern. The flexible plenum insulates the transmission path of any vibration and noise produced by the motor blower protecting sensitive cells and reducing noise pollution. The HEPEX material is tear and abrasion-resistant, flame retardant, and impermeable to gases, fluids, and dust reducing contamination risks making it the perfect solution for biomedical/microbiological and hazardous drug compounding work. All filter seals are kept under negative pressure. In the event of a potential leak, air will recirculate back through the motor blower and into the plenum.
Monolithic Construction
At the heart of any NuAire biosafety cabinet is its construction. The NuAire design centers on the use of high-quality stainless steel and seam welding to eliminate leak risks that come with the use of multi-piece shells put together with gaskets, sealants, and rivets. The NuAire BSC uses a coved stainless steel interior inserted into a larger wrap that makes up the cabinet walls. The top and bottom catch tray is seam welded into place, creating a monolithic leak-free cabinet shell designed to provide long-lasting maximum safety.
Configuration
Blower Contact Wires: Optional
Closure Panels: Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through: Standard Right, Optional Left
Double Exhaust HEPA Filter: N/A
Gas Supply Interlock with Blower: N/A
Glass Sidewalls: N/A
IV Bar with 6 Hooks: Optional
Magnifying Glass in Window: N/A
Motorized Base Stand: Optional as Separate Accessory
Motorized Window: N/A
Other Built-in Supply Filter Option(s): N/A
Outlet(s): Standard, two backwall
Plumbing: Optional 3/8 Soft Copper, 3/8 Black Pipe (Gas Only), or 1/2 Rigid Copper
Remote Service Valves: N/A
Seismic Brackets or Studs: Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT): Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT): One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels: Optional with Plumbing out Bottom, Top or Back
Smooth Interior: N/A
Ultraviolet (UV) Light: Optional
Window Edge Protector: Optional
Construction
Access Opening Glass Type: Tempered
Armrest: Standard Plastic with Optional Stainless Steel
Cabinet Construction: All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters: N/A
Decontamination Seal-able Window: N/A
Diffuser: Metal, non-flammable
Drain Valve Location: Front right
Exhaust Filter: 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material: Painted Steel
HEPA Filter Seal Type: HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting: LED
Main Cabinet Wrap: Single Piece Stainless Steel Side and Back Wall Construction
Motor(s): 1/2 HP DC ECM
Plenum Type: HEPEX
Pre-filter: N/A
Style: Bench top, optional base stand
Supply Filter: 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm): 21 (533) open to fully closed
Work Access Opening(s): 8, 10-inch (203, 254 mm)
Work Surface: One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap: Single Piece Stainless Steel Side and Back Wall Construction
Controls and System Features
Data Output Features: RS-232
Remote Alarm Terminals: Standard
Dimensions
Est. Shipping Depth Inches (mm): 43 (1092)
Est. Shipping Height Inches (mm): 71 (1803)
Est. Shipping Width Inches (mm): 59 (1499)
Exterior Depth Inches (mm): 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm): 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm): 59 (1499)
Exterior Height Inches (mm): 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm): 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm): 93.375 (2371)
Exterior Width Inches (mm): 53 5/8 (1362)
Nominal Width Feet (Meters): 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm): 20 7/8 (530)
Useable Work Tray Area Width Inches (mm): 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm): 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm): N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm): N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm): Inquire
Work Area Height Inches (mm): 28 1/2 (724)
Work Area Width Inches (mm): 46 3/8 (1178)
Electrical
Blower/Lights Amps [10-inch (254 mm) Access Opening]: 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]: 2.6
Electrical Configuration: 115V, 60Hz
Junction Box: Optional
Outlet Amps: 3
Power Cord: Single 12-foot (3.7 m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter): 12 (3.7)
Rated Amps: 12
Ergonomics
Light Intensity fc (Lux): 90-120 (968-1291)
Reach into workzone Inches (mm): 6 (152)
Sound Pressure Level per ISO 4871 56 dba
Exhaust
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH): 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH): 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH): N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH): N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH): N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH): N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH): 359 (610)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH): 295-520 (502-884)
Bag In Bag Out: N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour): 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour): N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour): N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour): 1020
Heat Rejected Vented (BTU/Hour): 157
Other Built-in Exhaust Option(s): N/A
Plant Duct Static Pressure Inches (mm): 0.05-0.1/1.27-2.54mm H2O
Performance
Air Cleanliness (ISO 14644): ISO-Class-5
Downflow fpm (m/s): 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures: True
Inflow fpm (m/s): 105 fpm (0.53 m/s)
Protection: Product, Personnel, Environmental
Technology
Airflow Monitor: Pressure
Control System: AeroMax
Additional Prep Fees May Apply