WATERS 2489 UV Visible Detector | Testing and Analyzing Equipment
    $2,249.00
    $1,687.00

    We'll submit your offer right away and will let you know as soon as the seller responds

    Want to speak to the seller?
    Call us at 1-847-854-8577

    Did you know?

    • Buy This Now will submit at asking price
      BoE will be in contact within 1 business day.
    • This is NOT a timed auction.
    • BoE highly recommends buyers Contact the Seller to get questions answered prior to placing an offer.

    Item Details

    Item Id 405437
    Item #: 405437
    Item: WATERS 2489 UV Visible Detector
    Model #: 2489
    Serial #: N/A
    Year Built: N/A
    Location: California
    Price: $2,249.00

    Description

    Waters 2489 UV/Visible Detector 186002487

    **This instrument has been tested for basic power function. Unit does NOT include software. See photos for further details.

    The Waters 2489 UV/Visible detector can be used for in vitro diagnostic testing to analyze many compounds, including diagnostic indicators and therapeutically monitored compounds.

    The Waters 2489 UV/Visible Detector is a two-channel ultraviolet/visible (UV/Vis) detector designed for high-performance liquid chromatography (HPLC) applications

    The detector can operate either as a stand-alone unit (with a chart recorder or integrator) or as an integral part of a Waters chromatography system. The detector can be configured with Empower or MassLynx software systems.

    Features:
    The detector operates from 190 to 700 nm. Also, the instrument uses optics with an enhanced illumination system for improved performance. These design features increase the optical throughput and sensitivity and reduce bandwidth for an overall increase in signal-to-noise ratio and improved linearity.

    The detector has the following capabilities:
    -Stand-alone programmability Stores up to five user-defined programs (or methods) consisting of up to 50 programmable timed events and two threshold events each.

    -Single or dual wavelength Monitors absorbance at one or two discrete wavelengths.

    -Wavelength verification reference filter Ensures wavelength accuracy.

    -Automatic second order filter Automatically engaged for wavelengths 370 nm and greater and removed for wavelengths 369 nm or less.

    -Spectrum scan and storage Supports spectrum scan, display, subtraction, storage, and playback, in addition to standard absorbance and UV/Vis functionality.

    -Cuvette qualification Facilitates qualification of the detector by insertion of a standard in a cuvette without breaking any fluid line connections. Waters qualification kits are available to support this feature. This feature also allows you to use the detector as a benchtop spectrophotometer.

    -Cuvette sample analysis Allows the spectrum of any sample placed in the cuvette to be recorded.

    -Method editing and storage Supports basic method programming, storage, and retrieval from the front panel.

    -Full diagnostic capability Supports built-in diagnostic tools to optimize functionality and performance.

    -Two contact closure outputs The detector has two configurable switches, each of which can accommodate a maximum of +30 Vdc, 1.2-A current carry, and 0.5-A current switching. The switches (SW1 and SW2) can trigger fraction collectors and other external devices, as well as activate based on time, absorbance threshold, or ratio criteria.

    -Improved thermal wander management To mitigate thermal instability caused by ambient temperature changes, the detector has improved insulation (for better air flow across the optics bench) and a variable speed fan that will run at higher or lower speeds as needed.

    -Median Baseline Filter (MBF) - A variation of the data mode, the MBF is intended to decrease the effects of gradient separations on the chromatographic baseline. The MBF enhances the UV detector's baseline stability by decreasing its curvature, making the development of integration methods easier.

    The Waters 2489 UV/Visible Detector is the best detection choice for performance, reliability, and usability. The 2489 UV/Vis Detector is the most sensitive and versatile dual-wavelength absorbance detector available for HPLC. The design combines a high-energy Deuterium source, a precise optical design, and low noise, high-speed electronics. These advanced capabilities take UV/Vis detection performance to a new level.

    Manufacturers Specifications:
    Wavelength range 190 to 700 nm
    Bandwidth <5 nm
    Wavelength accuracy +1.0 nm
    Wavelength repeatability +0.1 nm
    Single dry noise <5 AU
    (at 230 nm, 1 second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
    Wet noise <8 AU
    (at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
    Dual channel noise (dry)<12 AU
    (at 230 nm, 280 nm with 2-second filter at 1-Hz
    data rate, dry cell)
    Dual channel noise (wet)<15 AU
    (at 230 nm, 280 nm with 2-second filter at 1-Hz data rate, 1mL/min. flow of acetonitrile, analytical cell)
    Linearity <5% at 2.5 AU, propylparaben at 257 nm
    Drift 1.0 x 10-4 AU/hr. max (T = +2C/hr.)
    Thermal drift 1.0 x 10-4 AU/C max (T = +2C/hr.)
    Sensitivity setting range 0.0001 to 4.0000 AUFS
    Filter setting range Single-wavelength: 0.1 to 5.0 seconds
    Dual-wavelength: 1 to 50 seconds
    Time-constant To 5.0-second Hamming filter
    Digital data rates 1,2,5,10,20,40,80 Hz (single channel)
    1,2 Hz (dual channel)
    Analog output data rates (single mode) 10,20,40,80 Hz (channel A)
    10 Hz only (channel B)
    Lamp source 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
    Second-order filter Automatic for wavelengths > 370 nm
    Wavelength calibration filter Erbium filter, used at startup or on demand
    Flow cell TaperSlit flow cell design
    Nitrogen purge Purge fitting present on optics bench
    Path length 10 mm (standard analytical)
    Cell volume 10 L (standard analytical)
    Pressure limit 6895 kPa (69 bar,1000 psi)
    Operating temperature 4 to 40 C (39 to 104 F)
    Operating humidity 20% to <95%, noncondensing

    Additional Prep Fees May Apply

    Shipping

    Height: 8.00 in
    Width: 11.00 in
    Length: 20.00 in
    Weight: 21.00 lbs
    Prep Fee: N/A
    Registered Customers can request shipping quotes free of charge. Shipping Quotes take 1-3 Business Days to Process
    Request Shipping Quote

    charticon This item has  today
    moneyicon Have one to sell?
    Sell
    Need Financing? FinanceLink

    Testimonials

    • "The biggest demand for manufacturers today is to become operational as quickly as possible and Bid on Equipment provides this solution." - Dave M.
    • "The strength of their site is how often our machinery comes up on web searches." - John G.
    • "We appreciate BoE... Always helpful, friendly and very professional." - Ali L.
    • "If you have questions about machinery you're buying they will find someone who can help. Everyone I talk to here is very friendly." - Tim Y.
    • "BoE is a powerful site that has yielded great results for our company. If you need to buy or sell equipment, I recommend this site." - Michael M.
    • "BoE keeps the engine turning and its potential is limitless. They take out the nonsense that you find on auction sites." - George P.
    • "I have sold 2 large Electric Motors through Bid On Equipment. They got them sold within a month!" - Richard B.
    • "The best thing to happen to our company, the personnel are fantastic..." - Ron W.