THERMO SCIENTIFIC Dionex ICS-Series VWD Variable Wavelength Detector | Testing and Analyzing Equipment
    $1,249.00
    $937.00

    We'll submit your offer right away and will let you know as soon as the seller responds

    Want to speak to the seller?
    Call us at 1-847-854-8577

    Did you know?

    • Buy This Now will submit at asking price
      BoE will be in contact within 1 business day.
    • This is NOT a timed auction.
    • BoE highly recommends buyers Contact the Seller to get questions answered prior to placing an offer.

    Item Details

    Item Id 410316
    Item #: 410316
    Item: THERMO SCIENTIFIC Dionex ICS-Series VWD Variable Wavelength Detector
    Model #: Dionex ICS-Series VWD
    Serial #: N/A
    Year Built: N/A
    Location: California
    Price: $1,249.00

    Description

    Thermo Scientific Dionex ICS-Series VWD Variable Wavelength Detector P/N 070220

    **This instrument was tested as far as we could. Unit is able to connect and communicate with software. Buyer can expect the same unit pictured and 30-day warranty. Does NOT include software. See photos for details.

    (Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)

    The Thermo Scientific Dionex ICS Series Variable Wavelength Detector (Dionex VWD) is a high-quality instrument designed for IC analysis applications requiring a UV-Vis detector and for LC analysis applications requiring an inert (PEEK) flow path. The Dionex VWD can be used with the following Thermo Scientific Dionex systems: the ICS-5000 (analytical systems only), ICS-2100, ICS-1600, ICS-1100, and ICS-900 (as well as some legacy systems). The Dionex VWD can be used in numerous laboratory environments for routine analysis, as well as for sophisticated research tasks.

    Two versions of the Dionex VWD are available: a single channel version.
    (P/N 070220) and a four-channel version (P/N 070221).

    The detector is a dual-beam, variable-wavelength photometer with one measurement and one internal reference beam.

    Two light sources, a deuterium lamp for ultraviolet detection and a tungsten lamp for visible and near-infrared wavelength detection, provide a wavelength detection range from 190 to 900 nm.

    The four-channel detector measures at up to four wavelengths, by indexing between wavelengths several times per

    The wavelength accuracy can be verified via the built-in holmium oxide filter.

    The detector is controlled with a PC (personal PC) running Microsoft Windows Vista or Windows XP and either the Thermo Scientific Dionex Chrome Leon 7 Chromatography Data System or Chrome Leon 6.8 Chromatography Data System. Chrome Leon 7 and Chrome Leon 6.8 also provide data acquisition and data processing functions.

    NOTE Thermo Scientific Dionex Chrome Leon Xpress software can provide real-time control and monitoring of the detector but does not include data management capabilities.

    Manufacturer's Specifications:
    Optical System Double-beam forward optics design (monochromator)
    Dual-wavelength UV-VIS detector
    Light Sources Deuterium lamp (for ultraviolet wavelength detection)
    Tungsten lamp (for visible wavelength detection
    Wavelength Range 190 to 900 nm

    Wavelength
    Accuracy 1 nm (over detector lifetime)

    Wavelength
    Repeatability 0.1 nm

    Noise (single wavelength) < 3.5 AU (typical < 2.5 AU) under the following conditions:
    Dry (dummy) flow cell, 254 nm, 1 second time constant, deuterium lamp on only, 60 minutes or less of warm-up time

    < 5.0 AU (typical) under the following conditions:
    Dry (dummy) flow cell, 520 nm, 1 second time constant, tungsten lamp on only, 60 minutes or less of warm-up time

    < 7.5 AU (typical) under the following conditions:
    Wet standard cell, 520 nm, flowing methanol at 1.0 mL/min, 1 second time constant, tungsten lamp on only, 60 minutes or less of warm-up time

    Noise (dual wavelength< 25 AU (typical < 10 AU) under the following conditions:
    Dry (dummy) flow cell, 254 and 280 nm, 2 second times constant,
    2 Hz data collection rate, deuterium lamp on only, 60 minutes or less of warm-up time

    < 30 AU (typical < 10 AU) under the following conditions:
    Dry (dummy) flow cell, 450 and 520 nm, 2 second times constant, 2 Hz data collection rate, tungsten lamp on only, 60 minutes or less of warm-up time

    < 50 AU (typical < 10 AU) under the following conditions:
    Wet standard flow cell, 450 and 520 nm, flowing methanol at 1.0 mL/min, 2 second time constant, 2 Hz data collection rate, tungsten lamp on only, 60 minutes or less of warm-up time

    Drift<1 x 10-4 AU/hour under the following conditions:
    Dry (dummy) flow cell, 254 nm, deuterium lamp on only, 60 minutes or less of warm-up time, constant ambient conditions (Temperature, humidity)

    <1 x 10-4 AU/hour under the following conditions:
    Dry (dummy) flow cell, 520 nm, tungsten lamp on only, 60 minutes or less of warm-up time, constant ambient conditions (Temperature, humidity

    Wavelength
    Calibration Internal calibration with zero order and D-alpha line of the deuterium lamp

    Wavelength
    Verification Internal verification with holmium oxide filter

    Data Collection
    Rate (single wavelength) Adjustable, up to 10 Hz (single-channel Dionex VWD) or 100 Hz (Four-channel Dionex VWD)

    Data Collection
    Rate (multiple wavelength) Adjustable, up to 5 Hz, depending on the number of wavelengths.
    (2 to 4) and the distance between the wavelengths (in nm)

    Optical Bandwidth 6 nm at 254 nm

    Identification
    System Storage of identification and status information, including the lamp type, serial number, number of lamps starts, lamp age, and lamp intensity

    Digital I/O
    Inputs Four digital inputs
    Outputs Four digital outputs

    Manual

    Additional Prep Fees May Apply

    Shipping

    Height: 7.00 in
    Width: 18.00 in
    Length: 20.00 in
    Weight: 33.00 lbs
    Prep Fee: N/A
    Registered Customers can request shipping quotes free of charge. Shipping Quotes take 1-3 Business Days to Process
    Request Shipping Quote

    charticon This item has  today
    moneyicon Have one to sell?
    Sell
    Need Financing? FinanceLink

    Testimonials

    • "The biggest demand for manufacturers today is to become operational as quickly as possible and Bid on Equipment provides this solution." - Dave M.
    • "The strength of their site is how often our machinery comes up on web searches." - John G.
    • "We appreciate BoE... Always helpful, friendly and very professional." - Ali L.
    • "If you have questions about machinery you're buying they will find someone who can help. Everyone I talk to here is very friendly." - Tim Y.
    • "BoE is a powerful site that has yielded great results for our company. If you need to buy or sell equipment, I recommend this site." - Michael M.
    • "BoE keeps the engine turning and its potential is limitless. They take out the nonsense that you find on auction sites." - George P.
    • "I have sold 2 large Electric Motors through Bid On Equipment. They got them sold within a month!" - Richard B.
    • "The best thing to happen to our company, the personnel are fantastic..." - Ron W.