Thermo Scientific Vanquish Diode Array Detector FG P/N VF-D11-A
**Brand new in box! Flow cell not included.
Get the best performance, reliability, and flexibility in HPLC and UHPLC detection with Thermo Scientific Vanquish Diode Array Detectors (DAD) and Multiple Wavelength Detectors (MWD). These detectors offer excellent linearity and optimized noise performance, and feature an ultra-wide dynamic range to allow detection of highly concentrated main compounds alongside trace-level impurities.
In addition, the Vanquish DAD HL uses Thermo Scientific LightPipe technology to achieve the best signal-to-noise performance through a combination of low baseline noise, a very long light path, and minimal dispersion
Vanquish DAD features
Industry leading linearity with up to 2.7 AU
Reduced interfering refractive index and thermal effects means less baseline drift and more reliable peak integration.
Data acquisition at rates up to 250 Hz using up to 10 absorption channels and one spectral field delivers the best support of ultrafast separations.
Easy-to-use detector with intuitive user interaction, convenient flow cell and lamp usage tracking, and the integrated wavelength validation through holmium oxide filter.
Manufacturer's Specifications:
Description Vanquish Diode Array Detector FG
Data Collection Rate Up to 250 Hz
Detection Mode UV-vis Detection (Up to 10 Channels)
Detector Type Single-Beam
Type Diode Array Detector
Drift < 1 mAU/hour at 254 nm
Flow Cell Volume Standard, path length 10 mm (13 L, SST)
Standard, biocompatible, path length 10 mm (13 L, PEEK)
Semi-analytical, path length 7 mm (5 L, SST)
Semi-micro, pathlength 7 mm (2.5 L, SST)
Semi-micro, biocompatible, path length 7 mm (2.5 L, titanium)
Diagnostic cell
GLP Features Predictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
Lamp Deuterium lamp, tungsten lamp
Linearity < 5% at 2.2 AU (typically < 5% at 2.7 AU)
Max. Cell Operating Pressure Standard biocompatible: 5 MPa (50 bar, 720 psi)
Other flow cells: 12 MPa (120 bar, 1740 psi)
Noise < 6 AU at 254 nm (standard flow cell, bandwidth: 4 nm, slit width: wide, time constant: 2 sec)
No. of Channels 10 + 3D field
PC Connection USB 2.0; 3-port HUB to connect further Vanquish modules
Photodiode Array 1024 element
Safety Features Power-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit Width Settable: Wide, narrow
Spectral Bandwidth Pixel resolution: 0.6 nm (average)
Temperature Range 5 to 35C; 20 to 80% RH (non-condensing)
Validation Functions Internal validation with holmium oxide filter
Wavelength Accuracy 1 nm
Wavelength Range 190800 nm
Wavelength Repeatability 0.1 nm
Weight (Metric) 16.3 kg
Electrical Requirements 100240 V AC, 50/60 Hz, max. 245 W / 255 VA
Unit Size Each
Additional Prep Fees May Apply