    Description

    Thermo Scientific Velos Pro Mass Spectrometer System w/ Vacuum Pumps E2M30

    ***Unit was tested as far as we could. Unit is preowned with minimal wear from normal use. System will need to be validated/calibrated to ensure accurate results. Inquire if validation/calibration is available for an additional cost. Buyer can expect everything pictured with 30-day warranty. See photos for details.

    (Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)

    Includes:
    Velos Pro
    Edwards E2M30 Vacuum Pumps (Qty: 2)
    Ion Max API source

    The Velos Pro mass spectrometer is an optimized dual-cell linear ion trap with high-pressure and low-pressure cells that blurs the lines between traditional ion trap and triple quadrupole performance.

    The first high-pressure cell enables maximum ion trapping efficiency, higher ion isolation and fragmentation efficiency. The second low-pressure cell, enables better resolution and higher scan rates. All of which, results in higher sensitivity for full scan MS and MSn analysis.

    If you are in the market for an extremely powerful and flexible mass spectrometer, look no further than the Velos Pro dual-cell linear ion trap.

    Applications include:
    proteomics, metabolite identification, forensic analysis, clinical research and teaching.

    A single quadrupole offers no more than Selected Ion Monitoring (SIM). A triple quadrupole adds Selected Reaction Monitoring (SRM) where a selected ion can be fragmented into a product ion. A linear ion trap goes further by enabling Consecutive Reaction Monitoring (CRM) where a selected ion is fragmented into a product ion and the resulting product ion further fragmented in additional consecutive steps (MSn). Each additional fragmentation step makes compound identification more certain and facilitates structural characterization.

    Hardware features
    Thermo Scientific Ion Max API source
    With ESI, HESI, APCI and APPI options
    Sweep gas reduces chemical noise
    60 interchangeable ion probe orientation
    Removable metal ion transfer tube provides vent-free maintenance

    Transfer ion optics
    S-lens technology
    Generation II Ion optics with novel neutral blocking technology for improved robustness
    High stability and ion transmission efficiency

    Dual-pressure 2D linear quadrupole ion trap mass spectrometer
    Dual-pressure for optimized performance
    Isolation waveforms during injection
    Balanced rf field
    Automatic system calibration
    High-efficiency radial ion ejection

    Vacuum system
    Differentially-pumped vacuum system to 105 Torr
    Split-flow turbomolecular pump controlling vacuum in three regions
    Dual rotary vacuum pump configuration
    High-vacuum aluminum analyzer chamber

    Detection system
    Proprietary dual conversion dynode detector
    Two off-axis discrete dynode electron multipliers with extended dynamic range
    24-bit electrometer for high level linearity
    Digital electronic noise discrimination

    Integrated liquid delivery
    Fully-automated data system with valve control enables user to divert the solvent front, gradient end point, and any other portion of the HPLC run to waste
    Syringe Pump allows automated infusion under data system control

    Data system features
    Hardware
    High performance PC
    27 inch LED Monitor with 1920 x 1080 resolution
    Operating system
    Microsoft Windows 10 x 64 enterprise IoT LTSB 2016 Thermo Scientific software
    LTQ Instrument Control Software
    Thermo Scientific Xcalibur software for method setup, data acquisition, data processing, and reporting
    Thermo Scientific FreeStyle software to view and analyze data

    Scan functions
    Predictive Automatic Gain Control (AGC) delivers up to 10 Hz data dependent MS/MS acquisition
    Full-scan mass spectra for sensitive analyses and rapid screening of unknown compounds
    Full-scan product ion spectra at sensitivities higher than any ion trap mass spectrometer
    Selected Reaction Monitoring (SRM) for traditional LC/ MS/MS quantitative analytical experiments
    MSn for multi-stage MS experiments to probe the structure of ions
    ZoomScan, a high-resolution, full-range scan to resolve isotopic envelopes often used for charge state
    determination
    Ultra ZoomScan for ultimate resolution
    Rapid Scan, the fastest scan mode for UPLC analytical data collection
    TurboScan an ultra-fast scan to improve signal-to-noise and sampling rate
    Unique Automatic Gain Control (AGC) ensures that the ion trap is always filled with the optimum number of
    ions for any scan type
    Dynamic Exclusion allows acquisition of MS/MS and MSn spectra from lower intensity ion species
    WideBand Activation generates more structurally informative spectras
    Normalized Collision Energy provide reproducible data from instrument to instrument

    System specifications
    MS/MS sensitivity
    Heated electrospray ionisation (HESI) 2 L of a 50 fg/L solution of reserpine (100 femtograms total)
    injected at a flow of 400 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the
    isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when
    the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165650.

    Atmospheric pressure chemical ionization (APCI)
    2 L of a 50 fg/L solution of reserpine (100 femtograms total) injected at a flow of 400 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the fullscan MS/MS mode, scanning the product ion spectrum from m/z 165650.

    MSn sensitivity
    Heated electrospray Ionization (HESI) A loop injection of 2 L of a 50 fg/L solution of reserpine (100 femtograms total sample) at a flow of 400 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the unit isolated protonated molecular ion at m/z 609 to the product ion at m/z 397 which is further fragmented to the product ion at m/z 365, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165650.

    Installation requirements
    Power
    One 230 Vac 10.0%, 15 Amps, 50/60 Hz, single phase, with earth ground dedicated to the instrument
    120 or 230 Vac single phase, with earth ground for the data system

    Gas
    One high-purity (99% pure, flow rate 15 L/min) nitrogen gas supply for the API source
    One ultra-high-purity helium gas supply (99.998% pure) with less than 1 ppm each of water, oxygen, and total hydrocarbons for the mass analyzer

    Environment
    System averages 2300 W (8000 BTU/h) output when considering air conditioning needs
    Operating environment must be 1527 C (5980 F) and relative humidity must be 4080% with no condensation
    Optimum operating temperature is 1821 C (6570 F)

    Dimensions/weight
    MS: 56 cm 79 cm 59 cm (h w d)
    MS: ~120 kg
    Two roughing pumps: 38.6 kg each

    Performance specifications
    Mass range
    m/z 15200
    m/z 502000
    m/z 2004000

    Linear dynamic range
    Under typical experimental conditions, at least six (6) orders of magnitude

    Polarity switching
    100 msec between positive and negative

    Scan power
    MSn
    or n = 1 through 10

    Contact closure
    Start In/Out
    Start Out is programmable

    Analog inputs
    One (1) analog Input (01 V)
    One (1) analog Input (010 V)

    Additional Prep Fees May Apply

    Shipping

    Height: 22.00 in
    Width: 50.00 in
    Length: 25.00 in
    Weight: 500.00 lbs
    Prep Fee: N/A
    Registered Customers can request shipping quotes free of charge. Shipping Quotes take 1-3 Business Days to Process
    Request Shipping Quote

    charticon This item has  today
    moneyicon Have one to sell?
    Sell
    Need Financing? FinanceLink

    Testimonials

    • "The biggest demand for manufacturers today is to become operational as quickly as possible and Bid on Equipment provides this solution." - Dave M.
    • "The strength of their site is how often our machinery comes up on web searches." - John G.
    • "We appreciate BoE... Always helpful, friendly and very professional." - Ali L.
    • "If you have questions about machinery you're buying they will find someone who can help. Everyone I talk to here is very friendly." - Tim Y.
    • "BoE is a powerful site that has yielded great results for our company. If you need to buy or sell equipment, I recommend this site." - Michael M.
    • "BoE keeps the engine turning and its potential is limitless. They take out the nonsense that you find on auction sites." - George P.
    • "I have sold 2 large Electric Motors through Bid On Equipment. They got them sold within a month!" - Richard B.
    • "The best thing to happen to our company, the personnel are fantastic..." - Ron W.