Thermo Trace GC Ultra Gas Chromatograph K2523BB20C00710 (AS/IS for parts)
***Unit for sale AS/IS for parts. This unit powers on but is missing top, side, back panel & components. See photos for further details.
Your lab's analytical requirements are changing all the time. Here's a GC that can keep you a step ahead: the Thermo Scientific TRACE Ultra Gas Chromatograph. Configured with up to two injectors and three detectors, this multi-channel instrument combines the reliability of the TRACE platform with ultra performance and automation. The result is unmatched productivity, versatility and reliability plus the sensitivity you need for the most critical GC and GC-MS applications.
The Thermo Scientific TRACE GC Ultra multi-channel gas chromatograph was developed for the evolving requirements of modern laboratories. With the most complete range of proprietary inlets, sensitive detection systems, smart accessories, and ancillary devices, the Ultra platform features unique technologies that raise the standards of speed, sensitivity and separation in gas chromatography.
Features
Simple, rugged hardware
Internal LAN interfacing capability
Independently heated valve housing able to accommodate up to 4 heated/2 unheated gas valves, 8 pressure regulators, 8 needle valves, In/out ports, packed and capillary columns
Range of Large Volume techniques overcomes sensitivity boundaries of conventional GC
Linear heating rate up to 1200C/min. reduces sample run times for crude oils, pesticides and hydrocarbons determination as well as food and flavor characterizations
High temperature programming up to 20C/s and fast cooling times of approximately one minute
Precise retention time control
Large Volume split/splitless technique using standard splitless injector extends sample injection volume of conventional GC methods without additional investment, training or revalidation of methods
Supports range of injectors, including BEST PTV, cold on-column inlets and detector soltuions for conventional GC and GC/MS
Provides in-series, staked or parallel configurations of up to three detectors featuring different selectivity
Dedicated turnkey analyzers for chemical and petrochemical applications available
Specifications
Column Oven Programmability: 7 Ramps/8 Plateaus
Temperature Range: Near ambient to 450C
Maximum Temperature Ramp: 120C/min
Typical Heat-up: from 50 to 450C in 420 seconds
Typical Cool Down: 450 to 50C in 250 seconds
Sub-ambient: -99C with liquid N2, -55C with CO2options
Injectors
Vaporizing Inlets
SSL, Packed, Purged Packed
B.E.S.T. PTV Temperature Range: 50 to 400C
Heating Rate: Up to 14.5C/sec (870C/min)
Programmability: 3 ramps/4 plateaus
Air-cooled down to few degrees above ambient temperature
Sub-ambient: -50C with liquid N2, -30C with CO2options
Non-Vaporizing Inlets
Cold On-column Septumless injector. No heating of the injector is required.
Suitable for manual and automated operations. Cryogenic coolant not required.
Large Volume Options
Large Volume Cold On-column Up to 450L injectable volume. Uncoret type desolvation precolumn. Heated Solvent Vapor Exit valve.
LVI software assistant for parameter optimization. Suitable for clean matrices.
Large Volume B.E.S.T. PTV Up to 450L injection volume. Heated Solvent Split valve. Compatible with optional Backflush kit for PTV.
Suitable for large volatility range samples in dirty matrices.
Large Volume SplitlessUp to 50L injection volume. Compatible with manual or automated injections.
Suitable for samples amenable to split-splitless injector.
Inlet Pneumatics
Digital (250 and 1000kPa) Ambient Temperature and Pressure compensation. Gas saver. Assisted Leak Check Evaluation. Pressure surge.
Proprietary Algorithm for Column Characterization (Linear velocity and Void Time calculation)
Detectors
MDA Flame Ionization Detector: 2 x 10-12gC/sec
Thermal Conductivity Detector: 600pg Ethane/mL He
Electron Capture Detector: <10fg of Lindane
Nitrogen Phosphorus Detector: 5 x 10-14gN/s and 2 x 10-14gP/s
Flame Photometric Detector: 1 x 100-13gP/s and 104(P), 5 x 10-12gS/s (Malathion)
Photo Ionization Detector: 1 x 10-12g of Benzene, 1.3 x 10-12g of Toluene
Pulsed Discharge Detector: Low pg range
Linearity Flame Ionization Detector: Better than 10c
Thermal Conductivity Detector: 106
Electron Capture Detector: Better than 104
Nitrogen Phosphorus Detector: Better than 104
Flame Photometric Detector: 103(S) after linearization with suitable software
Photo Ionization Detector: Better than 10c
Pulsed Discharge Detector: 10c
Selectivity or Additional Features Flame Ionization Detector: Flameout detection and timed programming capability. Acquisition rate 300Hz
Thermal Conductivity Detector: Automated software switch function
Electron Capture Detector: 63Ni source, micro cell volume design
Nitrogen Phosphorus Detector: N/C = 10c:1; P/C = 2 x 10c:1
Flame Photometric Detector: P/C=106:1; S/C=10c:1, Dual flame photometric capability
Photo Ionization Detector: Lamp cooling system for temperatures up to 400C
Pulsed Discharge Detector: Non radioactive source
Additional Prep Fees May Apply