Beckman Coulter Clinical Chemistry Analyzer AU680 - Full System
***AU680 was tested as far as we could. Unit powers on and able to communicate with PC & software. Unit is preowned and in excellent condition with minimal wear from normal use. Buyer can expect everything pictured with 30-day warranty. See photos for details.
(Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)
Designed for flexibility in the laboratory
Meet ever-increasing pressures on time and productivity with ease. The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer delivers field-proven reliability and efficiency to laboratories around the world.
The AU680 intuitive graphical user interface includes:
Sample tracking
Patient statistics
User-customized menu
Color alerts to highlight system operating conditions
AU-proven reliability enables greater uptime with quick and easy parts replacement
No tools required
No more than three steps, no longer than 60 seconds, for parts such as sample and reagent probes, mixers and syringes
Online help videos guide the operator on proper technique when performing maintenance procedures and parts replacement, which enables greater system uptime
Additionally, the AU680 chemistry analyzer provides:
Integration of pre-analytical automation and immunoassay is attainable with AU680 Direct Track Sampling to Power Processor and connectivity to UniCel DxI 600/800 systems
Command Central integrated with REMISOLAdvance*enables remote monitoring of and access to instruments and automation consoles from a single workstation, optimizing laboratory management and improving decision-making
Cooled STAT compartment provides one-button STAT interrupt and advanced auto QC and calibration capabilities
High-precision microsampling provides accurate and precise results
Priority sample repeat/reflex reduces turnaround time for critical patients
Long-lasting ISEs minimize downtime and reduce operating costs
Large 150-sample rack loader provides for optimal sample processing during peak workload periods
Whole blood sampling capability is used for HbA1c testing
Manufacturer's Specifications:
Analytical System
Fully automated, random-access clinical chemistry system with STAT capability
Analytical Principles
Spectrophotometry and potentiometry
Analytical Types
Endpoint, rate, fixed point and indirect ISE
Analytical Methods
Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE
Simultaneously Processed Analytes
60 photometric tests + 3 ISE
Throughput
800 photometric tests/hour; up to 1,200 with ISE
Sample Types
Serum, plasma, urine, whole blood (HbA1c) and other fluids
Sample Feeder
Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading
Sample Tubes
In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
STAT Samples
Up to 22 positions for STAT samples, barcoded primary tubes
Sample Volume
125 L in 0.1 L increments (125 L for repeats)
Reagent Supply
60 positions for R1, 48 positions for R2; refrigerated: 412C; handling of 3-shot reagents
Reagent Volume
R1: 15250 L; R2: 15250 L; in 1 L increments
Total Reaction Volume
120425 L
Reaction Cuvette
Quartz cuvettes
Reaction Time
Up to 8 minutes, 40 seconds
Reaction Temperature
37C
Mixing Method
With rotating paddles after dispensing sample and reagent
Photometry System
Direct assay through the reaction cuvette (03.0 OD) mono and bichromatic measurements possible
Wavelength
13 different wavelengths between 340800 nm
Cuvette Cleaning
Comprehensive cleaning with detergents
Calibration
Auto calibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration)
Quality Control
Auto QC, cooled QC positions
Test Requisition
Individual and profile test requisition via online, mouse, function keys or touch screen
Safety
Clot detection and crash prevention for sample and reagent dispenser
Online
Full uni- and bi-directional communication possible
Software
Windows
Data Storage
Sample number: 100,000 samples. Reaction data: 200,000 tests.
Dimensions (WxHxD)
ANL 1,950x1,280x1,000
Power Supply
200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA
Additional Prep Fees May Apply