    Item Details

    Item Id 417280
    Item #: 417280
    Item: THERMO SCIENTIFIC OAS-3300TXRS Open Autosampler with Pump and Column Compartment
    Model #: OAS-3300TXRS, LPG-3400XRS, TCC-3000RS
    Serial #: N/A
    Year Built: N/A
    Location: California
    Price: $25,000.00

    Description

    Thermo Dionex UltiMate 3000 TXRS Open Autosampler w/ Pump & Column Compartment

    ***Unit is preowned with minimal wear from normal use. All units power on without errors, autosampler initializes upon startup. System will need to be validated/calibrated to ensure accurate results. Buyer can expect everything pictured working 100% with a 30-day warranty. See photos for details.

    (Please be advised that any warranty/guarantee/return policy provided from the seller is between the buyer and the seller only. Bid on Equipment is not and cannot be held responsible in any way. Please reference our Terms and Conditions for further information.)

    Includes:
    OAS-3300TXRS Open AutoSampler P/N 5485.0010
    TCC-3000RS Column Compartment P/N 5730.0000
    LPG-3400XRS Pump P/N 5043.0036

    The OAS-3300TXRS Open Autosampler is an XYZ robotic system offering high flexibility and functionality. The autosampler provides straightforward automation and sample handling in analytical UHPLC (ultra-high performance liquid chromatography) and mass spectrometry applications, especially as part of the UltiMate 3000 system. However, the instrument can also be used with other HPLC systems, if adequate control inputs and outputs are available.

    The autosampler is controlled by the Chromeleon Chromatography Management System.
    Being part of the UltiMate 3000 system, the autosampler can also be operated with other data systems, such as Analyst, Compass/ HyStar, or Xcalibur To do so, installation of the DCMSLink (Dionex Chromatography Mass Spectrometry Link) software is required in addition to the installation of the data system.

    Empower
    To do so, installation of the Dionex Instrument Integration software is required in addition to the installation of the data system.

    Operate at temperatures up to 110C with no compromise in precision or accuracy. The Thermo Scientific Dionex UltiMate TCC-3000RS Rapid Separation Thermostatted Column Compartment enables the use of high column temperatures for ultrafast and conventional liquid chromatography (LC) applications to reduce system backpressures and run times. Dispersion-reduced precolumn heating and postcolumn cooling technology ensure optimal separation, run time, and detection under challenging conditions. These low-volume cooling and heating components can be easily exchanged to optimally match column flow and mobile phase requirements.

    The TCC-3000RS Rapid Separation Thermostatted Column Compartment allows automated method development and column scouting to optimize column selection and other parameters. For existing methods, accurate and precise control of temperature from 5110C ensures consistent retention times, even as the ambient temperature changes. It is easily field-upgraded with up to two integrated column switching valves, providing access to advanced column switching techniques and two-dimensional LC (2D-LC) to increase productivity and performance. The high temperature range of this compartment expands the options for future methods.

    Features
    Optional column switching valves in stainless steel and PEEK support up to 125 MPa (1250 bar, 18,130 psi)
    Install precolumn heater and postcolumn coolers quickly and easily
    Postcolumn cooling minimizes detector noise and drift in ultrafast LC applications
    Fast heat up/cool down times minimize delays when changing methods
    Access to x2 dual technology increases productivity

    The TCC-3000RS is highly flexible and supports up to 12 LC columns (depending on column dimensions) to a length of up to 30cm. A column identification system simplifies audit trails and troubleshooting. It supports up to four columns, saving information such as column ID, geometry, media, number of injections, and more

    Description
    TCC-3000 RS Rapid Separation Thermostatted Column Compartment

    For Use With (Equipment)
    UltiMate 3000 RS Series

    Type
    Rapid Separation Thermostatted Column Compartment

    Voltage
    150 V

    Recommended Eluent Preheater Volume
    2 L

    GLP Features
    Dionex AutoQ routines for Instrument QualificationColumn Identification System for four columns

    I/O Interfaces
    2 digital inputs, 2 programmable relay outputs

    Cool-Down Time
    15 min.

    Max. Column Length
    30 cm

    Heat Up Time
    15 min.

    Column Capacity
    Up to 12 columns, depending on column length; Max. column length: 30 cm

    Max. No. of Switching Valves
    Up to 2 Valves: 2-position/6- or 10-port, 6-position/7-port

    Biocompatible Version
    Yes

    PC Connection
    USB

    Temperature Accuracy
    0.5C

    Temperature Range
    5C to 110C

    Weight (Metric)
    12.9 kg

    Unit Size
    Each

    For the highest degree of flexibility with solvent proportioning in UHPLC or conventional LC, the Thermo Scientific Dionex UltiMate LPG-3400RS Rapid Separation Quaternary Pump supports ternary and quaternary gradients over an industry-leading flow-pressure footprint. It supports the use of up to four solvents at up to 15,000 psi (100 MPa) and a recommended flow rate range from 200L to 8.0mL/min. with excellent flow stability. This pump adapts easily to multiple fast routine applications or method development in the pharmaceutical, food and beverage and environmental industries.

    Recommended Use
    The LPG-3400RS provides the highest degree of flexibility in solvent proportioning for UHPLC applications. This pump is recommended for a wide range of research and routine applications, and for method development. For higher-pressure separation needs, choose the LPG-3400XRS pump. For routine applications requiring up to 62 MPa (9,000 psi, 620 bar), choose the LPG-3400SD pump.

    Simple Method Transfer
    UltiMate 3000 Standard (SD) and RS pumps and system configurations provide similar gradient delay and extra-column volumes. This simplifies the method transfer between method development labs commonly using UHPLC pumps and QC and production labs with their standard LC pump configurations.

    Features
    Serial dual-piston operating principle, low-pressure gradient proportioning
    Wide operating flow rate range from 200L to 8mL/min. with high flow rate accuracy
    Support of operating pressures of up to 100MPa (15,000 psi/1000 bar)
    Thermo Scientific SmartFlow technology to automatically compensates for compressibility; no manual solvent setting needed
    Large selection of Thermo Scientific SpinFlow mixing volumes perfectly balance gradient delay volume with mixing efficiency
    Reliable vacuum degassing with an internal four-channel micromembrane degasser
    Active rear-seal wash to maximize seal lifetime and instrument uptime

    Description LPG-3400 RS Quaternary RS Pump
    Biocompatible Version Yes
    Flow Accuracy 0.1%
    Flow Precision <0.05% RSD or <0.01 min SD, whichever is greater
    Gradient Formation Low-Pressure Proportioning
    Max. Flow Rate 8 mL/min.
    Pressure Range 2 to 103.4 MPa up to 5 mL/min; 2 to 80 MPa up to 8 mL/min
    Type Serial Dual-Piston Quaternary Rapid Separation Pump
    Emission Sound Pressure Level <70 dB(A) in 1-m-distance
    For Use With (Equipment) 15-Pin D-Sub Connector for Solvent Rack/Degasser Connection
    GLP Features Full support of Thermo Scientific Dionex AutoQ instrument qualification, qualification status and system wellness monitoring. All system parameters are logged in the Chromeleon Audit Trail.
    Gradient Delay Volume 325-1840 L (Depending on the SpinFlow mixer configuration)Default: 690 L
    I/O Interfaces 2 digital inputs, 2 relay outputs
    Min. Flow Rate 0.001 mL/min. (Recommended: 0.1 mL/min.)
    No. of Eluent Lines 4
    Operating Principle Serial dual-piston
    PC Connection USB for PC connection, USB hub with 3 sockets integrated
    Pressure RippleTypically: <0.2 MPa or <1% whichever is greater
    Proportioning Accuracy 0.5% (full scale)
    Proportioning Precision <0.15% SD
    Solvent Degassing Built-in, 4 channels
    Overall Width (English) 16.5 in.
    Overall Width (Metric) 42 cm
    Overall Height (English) 6.3 in.
    Overall Height (Metric) 16 cm
    Overall Depth (English) 20 in.
    Overall Depth (Metric) 51 cm
    Weight (English) 29.8 lb.
    Weight (Metric) 13.5 kg
    Voltage 100-120 V, 60 Hz; 200-240 V, 50 Hz
    Frequency 100-120 V, 60 Hz; 200-240 V, 50 Hz
    Unit Size Each

    Additional Prep Fees May Apply

    Shipping

    Height: 46.00 in
    Width: 29.00 in
    Length: 28.00 in
    Weight: 1.00 lbs
    Prep Fee: N/A
    Registered Customers can request shipping quotes free of charge. Shipping Quotes take 1-3 Business Days to Process
    Request Shipping Quote

    charticon This item has  today
    moneyicon Have one to sell?
    Sell
    Need Financing? FinanceLink

    Testimonials

    • "The biggest demand for manufacturers today is to become operational as quickly as possible and Bid on Equipment provides this solution." - Dave M.
    • "The strength of their site is how often our machinery comes up on web searches." - John G.
    • "We appreciate BoE... Always helpful, friendly and very professional." - Ali L.
    • "If you have questions about machinery you're buying they will find someone who can help. Everyone I talk to here is very friendly." - Tim Y.
    • "BoE is a powerful site that has yielded great results for our company. If you need to buy or sell equipment, I recommend this site." - Michael M.
    • "BoE keeps the engine turning and its potential is limitless. They take out the nonsense that you find on auction sites." - George P.
    • "I have sold 2 large Electric Motors through Bid On Equipment. They got them sold within a month!" - Richard B.
    • "The best thing to happen to our company, the personnel are fantastic..." - Ron W.